Application material system
Vacuum Jacketed Piping & Cold Box
Prepare consistent insulation packages for long runs, bends, penetrations, valve boxes, and maintainable field joints.
East Far material scope
Relevant East Far products

CryoMLI 201
MLI construction for LN2 and argon applications, piping, cold boxes, and vacuum-jacketed systems.

CryoMLI 202
General cryogenic MLI for tanks, piping, cold boxes, superconducting cables, and research systems.

CryoMLI 212
Flexible MLI option for cryogenic vessels, piping, cold boxes, and power systems.

CryoTape AlF
Cryogenic aluminum-foil tape for localized fixing and securing of MLI in low-temperature systems.

CryoTape ACP
Cryogenic tape for MLI overlap sealing and lightweight fixing.

CryoTape FiG
Mechanical protection and reinforcement tape for cryogenic insulation packages.

CryoFiG Fabric
Outer protection and reinforcement fabric for cryogenic material packages.

CryoGetter / Vacuum Support
Vacuum-maintenance support for MLI plus adsorbent vacuum-insulation systems.
Engineering scope
Key engineering challenges
- Control layer density on small diameters and bends
- Avoid gaps at joints, valves, and supports
- Package slit and profile-cut materials for repeatable installation
System layers
- 01 Process line
Inner pipe, welds, supports, and field joints supplied by the piping system.
- 02 Wrapped MLI
CryoMLI slit and rewound to suit pipe diameter, bend radius, and installation method.
- 03 Seaming and reinforcement
CryoTape and CryoFiG control local edges and protect service-sensitive areas.
- 04 Vacuum jacket
Outer jacket, ports, and vacuum hardware remain part of the equipment design.
Supporting materials and supply boundaries
East Far Cryo supplies cryogenic insulation materials, related processing, and material-selection support. Equipment and system responsibilities remain with the project owner and equipment designer.
- Inner and outer pipe, spacers, bellows, field-joint closures, valves, and vacuum ports are not East Far Cryo-manufactured equipment.
- Sealants and structural thermal breaks require piping-designer approval.
- Adsorbent placement must remain serviceable and isolated from process contamination.
Parameters needed for quotation
- Cryogenic medium and normal / transient operating temperatures
- Target vacuum level, pump-down method, hold time, and expected residual-gas load
- Equipment geometry, dimensions or surface area, penetrations, and installation access
- Target heat leak or required layer count and any governing acceptance method
- Required delivery form: rolls, slit widths, sewn blankets, profile-cut parts, or installation kits
- Pipe diameters, straight-run lengths, bend radii, valve / joint geometry, and field-installation sequence
Downloads and technical contact
CryoMLI Series Product Brochure
Product structures, specifications, and application notes for CryoMLI materials.
CryoTape Series Product Brochure
Cryogenic tape structures, temperature ranges, and fixing recommendations.
MLI Technical Reference
Engineering reference for MLI material selection, vacuum, heat flux, and layer density.
We will review your application parameters and reply by email with any clarification questions and the next material-selection step.